玻璃绝缘子英文标准,全国咨询电话:400-700 - 3449 手机:1368 1123 585
Standard suspension insulator Fog type suspension insulator
Open Air Profile type suspension insulator Cap and Pin type suspension insulator
LXHP-70
Fog type suspension insulator
Zoom in
LXHP-70 Fog type suspension insulator
Currency designation U70BP/146H U70BP/146H U70BP/146H
Jinlihua designation LXHP4-160 LXHP5-160 LXHP6-160
( mm )Diameter D 255 280 320
( mm )Spacing H 146 146 146
( mm )Creepage L 400 450 550
( mm )Socket soupling 16 16 16
( kN )Mechanical failing load 70 70 70
( kN )Mechanical routine test 35 35 35
( kV )Wet power frequency withstand voltage 45 45 45
( kV )Dry lightning impulse withstand voltage 110 125 140
( P.U )Impulse puncture voltage 2.8 2.8 2.8
( kV )Power frequency puncture voltage 130 130 130
( µV )Rodio influence voltage 50 50 50
( kV )Electric iron visual test 18/22 18/22 18/22
Power frequency electric arc voltage 0.12s/20kA 0.12s/20kA 0.12s/20kA
( kg )Net weight per unit 4.6 5.8 9.2
LXHP-100 Fog type suspension insulator
Currency designation U100BP/146H U100BP/146H U100BP/146H
Jinlihua designation LXHP3-100 LXHP4-100 LXHP6-100
( mm )Diameter D 260 280 320
( mm )Spacing H 146 146 146
( mm )Creepage L 400 450 550
( mm )Socket soupling 16 16 16
( kN )Mechanical failing load 100 100 100
( kN )Mechanical routine test 50 50 50
( kV )Wet power frequency withstand voltage 45 45 45
( kV )Dry lightning impulse withstand voltage 110 125 140
( P.U )Impulse puncture voltage 2.8 2.8 2.8
( kV )Power frequency puncture voltage 130 130 130
( µV )Rodio influence voltage 50 50 50
( kV )Electric iron visual test 18/22 18/22 18/22
Power frequency electric arc voltage 0.12s/20kA 0.12s/20kA 0.12s/20kA
( kg )Net weight per unit 5.4 5.8 9.2
LXP-70 Standard suspension insulator
Zoom in
LXP-70 Standard suspension insulator
Currency designation U70B/140 U70B/146 U70B/127
Jinlihua designation LXP3-70 LXP1-70 LXP2-70
( mm )Diameter D 255 255 255
( mm )Spacing H 140 146 127
( mm )Creepage L 320 320 320
( mm )Socket soupling 16 16 16
( kN )Mechanical failing load 70 70 70
( kN )Mechanical routine test 35 35 35
( kV )Wet power frequency withstand voltage 40 40 40
( kV )Dry lightning impulse withstand voltage 100 100 100
( P.U )Impulse puncture voltage 2.8 2.8 2.8
( kV )Power frequency puncture voltage 130 130 130
( µV )Rodio influence voltage 50 50 50
( kV )Electric iron visual test 18/22 18/22 18/22
Power frequency electric arc voltage 0.12s/20kA 0.12s/20kA 0.12s/20kA
( kg )Net weight per unit 3.6 3.6 3.5

| 型 号 |
品 号 |
机械破坏
负荷
kN
不小于 |
打击破
坏负荷
N.cm
不小于 |
1h机电
负荷
试验值
kN |
公称
结构
高度
H |
绝缘件
公称
直径
D |
最小
公称
爬电
距离 |
雷电全
波冲击
耐受电压
(峰值)
kv,
不小于 |
工频电压
(有效值)
kv,
不小于 |
单件重量
kg |
| mm |
1min
湿耐受 |
击穿 |
LXY-70
LXY1-70 |
132202 |
70
70 |
565
565 |
52.5
52.5 |
127
146 |
255
255 |
320
320 |
100
100 |
40
40 |
130
130 |
3.77
3.78 |
| LXY-100 |
133201 |
100 |
678 |
75.0 |
146 |
255 |
320 |
100 |
40 |
130 |
4.10 |
| LXY-120 |
134205 |
120 |
678 |
90.0 |
146 |
255 |
320 |
100 |
40 |
130 |
4.20 |
| LXY3-160 |
135013 |
160 |
1017 |
120.0 |
155 |
280 |
380 |
105 |
42 |
130 |
6.20 |
| LXY3-210 |
136202 |
210 |
1017 |
157.5 |
170 |
280 |
390 |
105 |
42 |
130 |
6.70 |
| LXY-240 |
136206 |
240 |
1017 |
180.0 |
170 |
280 |
390 |
105 |
42 |
130 |
6.80 |
| LXY3-300 |
137201 |
300 |
1017 |
225.0 |
195 |
320 |
485 |
110 |
45 |
130 |
10.7 |

| 型 号 |
品 号 |
机械破坏负荷kN不小于 |
打击破坏负荷N.cm
不小于 |
1h机电负荷
试验值kN |
公称结构高度
H |
绝缘件
公称直径
D |
最小公称爬电距离 |
50%雷电冲击耐受电压(峰值)kv,不小于 |
工频电压(有效值)kv,不小于 |
单件重量
kg |
| mm |
湿耐受 |
击穿 |
LXHY4-70
LXHY-70 |
132605
132608 |
70
70 |
565
565 |
52.5
52.5 |
146
160 |
255
255 |
400
400 |
120
120 |
45
45 |
130
130 |
4.80
4.80 |
| LXHY5-70 |
132603 |
70 |
565 |
52.5 |
146 |
280 |
450 |
130 |
45 |
130 |
5.30 |
| LXHY4-100 |
133602 |
100 |
678 |
75.0 |
146 |
280 |
450 |
130 |
45 |
130 |
5.40 |
| LXHY4-120 |
134602 |
120 |
678 |
90.0 |
146 |
280 |
450 |
130 |
45 |
130 |
5.50 |
LXHY3-160
LXHY4-160 |
135605
135606 |
160
160 |
1017
1017 |
120.0
120.0 |
155
170 |
280
280 |
450
450 |
130
130 |
50
50 |
130
130 |
7.00
7.00 |
LXHY5-160
LXHY6-160 |
135603
135607 |
160
160 |
1017
1017 |
120.0
120.0 |
170
155 |
320
320 |
545
545 |
130
130 |
55
55 |
130
130 |
8.80
8.90 |
| LXHY3-210 |
136201 |
210 |
1017 |
157.5 |
170 |
320 |
545 |
130 |
55 |
130 |
9.23 |
| LXHY-300 |
137202 |
300 |
1017 |
225.0 |
195 |
340 |
545 |
140 |
55 |
130 |
12.20 |
| LXHY3-300 |
|
300 |
1017 |
225.0 |
195 |
380 |
635 |
155 |
60 |
130 |
14.30 |

| 型 号 |
品 号 |
机械
破坏
负荷
kN
不小于 |
打击
破坏
负荷
N.cm
不小于 |
1h机电
负荷
试验值
kN |
公称
结构
高度
H |
绝缘件
公称
直径
D |
最小公
称爬电
距离 |
雷电全
波冲击
耐受电
压(峰值)kv,
不小于 |
直流1min湿
耐受电
压(峰值)kv,
不小于 |
工频击
穿电压(有效值)kv,
不小于 |
单件
重量
kg |
| mm |
| LXZY-160 |
135901 |
160 |
10 |
120.0 |
170 |
320 |
545 |
140 |
65 |
130 |
9.6 |
| LXZY-210 |
136901 |
210 |
10 |
157.5 |
170 |
320 |
545 |
140 |
65 |
130 |
10.0 |
| LXZY-300 |
137901 |
300 |
10 |
225.0 |
195 |
400 |
635 |
150 |
70 |
140 |
14.3 |
| LXZY1-300 |
|
300 |
10 |
225.0 |
195 |
340 |
545 |
140 |
65 |
140 |
14.3 |

| 型 号 |
品 号 |
机械破坏负荷kN不小于 |
打击破坏负荷N.cm
不小于 |
1h机电负荷
试验值kN |
公称结构高度
H |
绝缘件
公称直径
D |
最小公称爬电距离 |
50%雷电冲击闪络电压(峰值)kv,不小于 |
工频电压(有效值)kv,不小于 |
单件重量
kg |
| mm |
湿闪络 |
击穿 |
| LXQY-120 |
134014 |
120 |
678 |
90.0 |
140 |
255 |
305 |
100 |
45 |
120 |
4.10 |
| LXQY-120 |
134015 |
120 |
678 |
90.0 |
146 |
255 |
305 |
100 |
45 |
120 |
4.11 |

| 型 号 |
品 号 |
机械破坏负荷kN不小于 |
打击破坏负荷N.cm
不小于 |
1h机电负荷
试验值kN |
公称结构高度
H |
绝缘件
公称直径
D |
最小公称爬电距离 |
50%雷电冲击闪络电压(峰值)kv,不小于 |
工频电压(有效值)kv,不小于 |
单件重量
kg |
| mm |
湿闪络 |
击穿 |
LXAY-120
LXAY1-120 |
134012
134016 |
120
120 |
678
678 |
90.0
90.0 |
146
140 |
390
390 |
360
360 |
100
100 |
50
50 |
120
120 |
5.30
5.30 |
| LXAY-160 |
135012 |
160 |
1017 |
120.0 |
146 |
390 |
360 |
100 |
50 |
120 |
7.00 |
| LXAY-210 |
|
210 |
1017 |
157.5 |
160 |
390 |
350 |
100 |
50 |
120 |
7.47 |

| 型 号 |
机械破坏负荷kN不小于 |
打击破坏负荷
N.cm
不小于 |
结构
高度
H |
公称
直径
D |
公称
爬电
距离 |
工频
湿耐受
电压 |
工频击穿电压 |
去掉上极地线绝缘子的工频闪络电压kv,不小于 |
地线绝缘子工频(干或湿)放电电压(间隙20mm)kv |
单件重量
kg |
| mm |
kv,不小于 |
干 |
湿 |
上限值 |
下限值 |
| LXDY-70CN |
70 |
565 |
200 |
160 |
160 |
30 |
110 |
45 |
25 |
30 |
8 |
|
| LXDY-100CN |
100 |
678 |
200 |
170 |
170 |
30 |
110 |
45 |
25 |
30 |
8 |
|

|
型 号
|
品 号 |
机械破坏负荷kN不小于 |
公称
结构
高度
H |
绝缘件
公称直径
D |
最小公称
爬电距离 |
雷电全波
冲击耐受
电压
(峰值)
kv,
不小于 |
工频电压
(有效值)
kv,不小于 |
0.32mg/cm2
盐密下人工污秽闪络电压kv不小于 |
单件
重量
kg |
| 弯曲 |
拉伸 |
mm |
1min
湿闪络 |
击穿 |
| LQBN2-25D |
163102 |
4 |
70 |
610 |
255 |
1260 |
300 |
150 |
- |
31.5 |
17.3 |
| LXY-70T |
132213 |
- |
70 |
146 |
255 |
320 |
100 |
40 |
110 |
- |
3.77 |
| LXHY-70T |
132606 |
- |
70 |
146 |
255 |
400 |
(120) |
(45) |
120 |
- |
4.80 |




|